High Availability and Rapid Recovery Protection

(HARRP) Server Requirements (5U Rack Mounted)

(Prerequisite: Database Server and/or Image Fileserver)

System Size Small Medium Large
Processor: Dual Intel® Quad Core Xeon Processor with 2x6MB Cache, 2.83GHz, 1333MHz FSB or better Dual Intel® Quad Core Xeon Processor with 2x6MB Cache, 2.83GHz, 1333MHz FSB or better Dual Intel® Quad Core Xeon Processor with 2x6MB Cache, 2.83GHz, 1333MHz FSB or better
Bus Type: PCI-E PCI-E PCI-E
Memory (RAM): 2 GB Fully Buffered DIMM'S at 667MHz Dual Ranked 4 GB Fully Buffered DIMM'S at 667MHz Single Ranked 4 GB Fully Buffered DIMM'S at 667MHz Single Ranked
Hard Disk: 3x146 GB Hot Swap drives with SAS interface (includes online spare). Drives should have < 10ms access time at 15 000 RPM. Effective disk space is 146 GB. 3x146 GB Hot Swap drives with SAS interface (includes online spare). Drives should have < 10ms access time at 15 000 RPM. Effective disk space is 146 GB. 3x146 GB Hot Swap drives with SAS interface (includes online spare). Drives should have < 10ms access time at 15 000 RPM. Effective disk space is 146 GB.
Drive Controller: Dual channel SAS 3.0Gb/s RAID controller with ≥ 256 MB cache. Configured for hardware RAID 1 fault tolerance with hot spare (software NOS controlled RAID 1 not recommended) and an one additional SAS RAID controller with external port configured for hardware RAID 5 fault tolerance (software NOS controlled RAID 5 not recommended). CD should operate from separate controller or channel 2 of controller. Dual channel SAS 3.0Gb/s RAID controller with ≥ 256 MB cache. Configured for hardware RAID 1 fault tolerance with hot spare (software NOS controlled RAID 1 not recommended) and an one additional SAS RAID controller with external port configured for hardware RAID 5 fault tolerance (software NOS controlled RAID 5 not recommended). CD should operate from separate controller or channel 2 of controller. Dual channel SAS 3.0Gb/s RAID controller with ≥ 256 MB cache. Configured for hardware RAID 1 fault tolerance with hot spare (software NOS controlled RAID 1 not recommended) and an one additional SAS RAID controller with external port configured for hardware RAID 5 fault tolerance (software NOS controlled RAID 5 not recommended). CD should operate from separate controller or channel 2 of controller.
Floppy Disk: N/A N/A N/A
Optical Drive: Multisession 24X CD-RW and DVD-ROM combo Drive Multisession 24X CD-RW and DVD-ROM combo Drive Multisession 24X CD-RW and DVD-ROM combo Drive
Network Interface: 1 LOM 10/100/1000 Mbps, compatible with the network operating system and cabling. 1 LOM 10/100/1000 Mbps, compatible with the network operating system and cabling. 1 LOM 10/100/1000 Mbps, compatible with the network operating system and cabling.
Redundancy: PSU PSU PSU
Ports: 1 serial, minimum 2 USB 1 serial, minimum 2 USB 1 serial, minimum 2 USB
Operating System: ARIA: Microsoft® Windows® Server 2003 R2 (Standard or Enterprise) with Service Pack 2 (5 client access license or sufficient seat licenses) ARIA: Microsoft® Windows® Server 2003 R2 (Standard or Enterprise) with Service Pack 2 (5 client access license or sufficient seat licenses) ARIA: Microsoft® Windows® Server 2003 R2 (Standard or Enterprise) with Service Pack 2 (5 client access license or sufficient seat licenses)
File System NTFS NTFS NTFS
Microsoft® OS Architecture 32-bit (not 64-bit) 32-bit (not 64-bit) 32-bit (not 64-bit)
Microsoft® .NET Framework ARIA(8.0 ≥ 8.5): 1.1and 2.0 (not 3.0) ARIA(8.6): 1.1, 2.0 and 3.0 ARIA(8.0 ≥ 8.5): 1.1and 2.0 (not 3.0) ARIA(8.6): 1.1, 2.0 and 3.0 ARIA(8.0 ≥ 8.5): 1.1and 2.0 (not 3.0) ARIA(8.6): 1.1, 2.0 and 3.0

Storage Array

System Size Small Medium Large
Hard Disk: 5x146 GB Hot Swap drives with Ultra-320 SCSI interface (includes online spare). Drives should have < 10ms access time at 15000 RPM. Effective disk space is 438 GB. 7x300 GB Hot Swap drives with Ultra-320 SCSI interface (includes online spare). Drives should have < 10ms access time at 15000 RPM. Effective disk space is 1.5 TB. 9x300 GB Hot Swap drives with Ultra-320 SCSI interface (includes online spare). Drives should have < 10ms access time at 15000 RPM. Effective disk space is 2.1 TB.
Redundancy: PSU PSU PSU
Additional Software: DoubleTake™ for Windows® Server Standard. One license required per server (3 licenses at minimum are required) DoubleTake™ for Windows® Server Standard. One license required per server (3 licenses at minimum are required) DoubleTake™ for Windows® Server Standard. One license required per server (3 licenses at minimum are required)
24U Half Height Rack systems come with the following components (see notes below):
  • 24U Short Rack
  • Cables for Keyboard and Video
  • NEMA standard power strip
  • 1U 8-port keyboard/monitor KVM switch box
  • 1U keyboard/trackball and monitor console
  • 2U 3000VA Uninterruptable Power Supply (UPS)
  • 24-port patch panel (CAT5E)

NOTES:

  1. Hardware used should be approved based on the current Microsoft® Windows Catalog Listing.
  2. 1 Gbps network recommended for maximum speed and performance.
  3. Optional full height rack available at extra cost.
  4. Primary and HARRP servers should not be placed in the same rack or location for optimum reliability.
  5. The Operating System (build and version) on the source servers shall match the Operating System (build and version) on the HARRP target server.
  6. Double-Take® Standard licenses only work with Windows® Standard Operating Systems.
  7. Double-Take® Advanced licenses only work with Windows® Advanced or Enterprise Operating Systems.
  8. Specifications subject to change without notice as newer computer models become available.

 

Contact Varian Oncology

Varian Oncology Headquarters
Tel: 1.650.424.5700
Contact Us

Events

  • 11/18/2008 - 11/21/2008
    Medica
  • 11/26/2008 - 11/29/2008
    AMPI Conference
  • 11/30/2008 - 12/05/2008
    RSNA 2008
  • 12/06/2008 - 12/09/2008
    ASH 2008 Annual Meeting (American Society of Hematology)

© 1999-2008 Varian Medical Systems, Inc. All rights reserved.
Production of any of the material contained herein in any format or media without the express written permission of Varian Medical Systems is prohibited.

North America EMEA - Europe, Middle East, India & Africa