Medical Oncology Database Server Recommendations (Tower or Rack - 2U)

Server Size Small
0-50 Concurrent Users
Medium
51-100 Concurrent Users
Large
100+ Users
Processor: Dual Intel® Xeon 5130 Dual Core Processors at 2.0 GHz, 1333MHz FSB with 4 MB cache. (or better) Dual Intel® Xeon 5130 Dual Core Processors at 2.0 GHz, 1333MHz FSB with 4 MB cache. (or better) Custom Hardware Quotation Required
Memory: 3 GB RAM 3 GB RAM
Hard Drives: 2x73 GB (OS/APP) + 2x73 GB (DB/LOG) + 1x146GB (DMP) Hot Swap drives Serial Attached SCSI interface at 15000 RPM. 2x73 GB (OS/APP) + 1x300 GB (DMP) – In chassis 4x73 GB (DB) + 2x73 GB (LOG) – External array. Hot Swap drives with drives Serial Attached SCSI interface at 15000 RPM.
Drive Controller: Single channel SAS RAID controller. Configured for hardware RAID 1 fault tolerance. Tape unit should operate from separate controller. One internal single channel SAS RAID controller. One external single channel SAS RAID controller. Configured for hardware RAID 1/10 fault tolerance. Tape unit should operate from separate controller.
CD-ROM/DVD: 24X CD-RW/DVD-ROM Drive 24X CD-RW/DVD-ROM Drive
Backup Tape: LTO-2 200/400 GB tape drive BrightStor™ ARCserve® 11.1 or later. LTO-2 200/400 GB tape drive BrightStor™ ARCserve® 11.1 or later.
Network Adapter: 1 NIC 100/1000 Mbps, compatible with the network operating system and cabling. 1 NIC 100/1000 Mbps, compatible with the network operating system and cabling.
Redundancy: PSU and Fans PSU and Fans
Ports: Minimum 2 USB Minimum 2 USB
Network Operating System: Microsoft® Windows® 2003 Standard Server, Service Pack 1, with sufficient client access licenses. Microsoft® Windows® 2003 Standard Server, Service Pack 1, with sufficient client access licenses.

Notes:

  1. Hardware used must be approved based on the current Microsoft® specifications.
  2. 1 Gbps network recommended for maximum speed and performance.
  3. Specifications subject to change without notice as newer computer models become available.

 

Contact Varian Oncology

Varian Oncology Headquarters
Tel: 1.650.424.5700
Contact Us

Events

  • 11/18/2008 - 11/21/2008
    Medica
  • 11/26/2008 - 11/29/2008
    AMPI Conference
  • 11/30/2008 - 12/05/2008
    RSNA 2008
  • 12/06/2008 - 12/09/2008
    ASH 2008 Annual Meeting (American Society of Hematology)

© 1999-2008 Varian Medical Systems, Inc. All rights reserved.
Production of any of the material contained herein in any format or media without the express written permission of Varian Medical Systems is prohibited.

North America EMEA - Europe, Middle East, India & Africa