Radiation Oncology Database Server Requirements (5U Rack Mounted -- Upgrades)

Processor:
Dual [Single or Multi] Core Intel® Xeon Processor 1MB (or greater) L2 Cache, 2.0GHz, 800 MHz or 1333MHz FSB
Bus Type:
PCI/PCI-E
Memory (DRAM):
4 GB Fully Buffered DIMM's, Dual Ranked, ECC
Hard Drives:
4x146 GB Hot Swap drives with Ultra-320 SCSI interface (includes online spare). Drive should have < 10ms access times at 15K RPM. Effective disk space 292 GB.
Drive Controller:
Dual channel Ultra-320 Configurable SCSI array controller with > 128MB cache. Configured for hardware RAID 5 fault tolerance and (50/50) read/write cache (Software RAID not recommended/supported). CD and LTO tape unit should operate from separate controller or channel 2 of SCSI controller.
Floppy Disk:
3.5" drive, 1.44 MB
Optical Drive (CD/DVD):
Multi-session 24X or greater with SCSI or IDE interface
Backup Tape:
LTO-2 200/400 GB, SCSI interface, internal drive unit, and BrightStor™ ARCserve® 2000 or later.
Network Interface:
1 LOM 10/100/1000Mbps, compatible with the network operating system and cabling.
Redundancy:
PSU and Fans
Ports:
1 serial, minimum 2 USB
Operating System:
ARIA:(8.0, 8.1, 8.5)
Windows® 2000 Server Standard, Service Pack 4 (Server 25 client access license or sufficient seat licenses), or Microsoft® Windows® Server 2003 R2 (Standard or Enterprise) with Service Pack 2 (25 client access license or sufficient seat licenses).
ARIA (8.6):
Microsoft® Windows® Server 2003 R2 (Standard or Enterprise) with Service Pack 2 (25 client access license or sufficient seat licenses).
File System:
NTFS
Microsoft® OS Architecture
32-bit (not 64-bit)
Microsoft® .NET Framework
ARIA (8.0, 8.1, 8.5): 1.1 and 2.0 (not 3.0)
ARIA (8.6): 1.1, 2.0 and 3.0
42U Half Height Rack systems come with the following components (see notes below):
  • Cables for Keyboard and Video
  • NEMA standard power strip
  • 1U 8-port keyboard/monitor KVM switch box
  • 1U keyboard/trackball and monitor console
  • 2U 3000VA Uninterruptible Power Supply (UPS)
  • 24-port patch panel (CAT5E)

Notes:

  1. Hardware used should be approved based on the current Microsoft® Windows® Catalog Listing.
  2. In addition to this Database Server, the following Image Fileserver is required for use with all image-based products and would be installed in the same rack.
  3. 1 Gbps network recommended for maximum speed and performance.
  4. The Operating System (build and version) on the Database Server shall match the Operating System (build and version) on the HARRP server.
  5. Specifications subject to change without prior notification.

 

Contact Varian Oncology

Varian Oncology Headquarters
Tel: 1.650.424.5700
Contact Us

Events

  • 11/18/2008 - 11/21/2008
    Medica
  • 11/26/2008 - 11/29/2008
    AMPI Conference
  • 11/30/2008 - 12/05/2008
    RSNA 2008
  • 12/06/2008 - 12/09/2008
    ASH 2008 Annual Meeting (American Society of Hematology)

© 1999-2008 Varian Medical Systems, Inc. All rights reserved.
Production of any of the material contained herein in any format or media without the express written permission of Varian Medical Systems is prohibited.

North America EMEA - Europe, Middle East, India & Africa