Oncology | Radiation Oncology
ARIA | Hardware Specifications
Radiation Oncology Database Server Requirements (5U Rack Mounted -- Upgrades)
- Processor:
- Dual [Single or Multi] Core Intel® Xeon Processor 1MB (or greater) L2 Cache, 2.0GHz, 800 MHz or 1333MHz FSB
- Bus Type:
- PCI/PCI-E
- Memory (DRAM):
- 4 GB Fully Buffered DIMM's, Dual Ranked, ECC
- Hard Drives:
- 4x146 GB Hot Swap drives with Ultra-320 SCSI interface (includes online spare). Drive should have < 10ms access times at 15K RPM. Effective disk space 292 GB.
- Drive Controller:
- Dual channel Ultra-320 Configurable SCSI array controller with > 128MB cache. Configured for hardware RAID 5 fault tolerance and (50/50) read/write cache (Software RAID not recommended/supported). CD and LTO tape unit should operate from separate controller or channel 2 of SCSI controller.
- Floppy Disk:
- 3.5" drive, 1.44 MB
- Optical Drive (CD/DVD):
- Multi-session 24X or greater with SCSI or IDE interface
- Backup Tape:
- LTO-2 200/400 GB, SCSI interface, internal drive unit, and BrightStor™ ARCserve® 2000 or later.
- Network Interface:
- 1 LOM 10/100/1000Mbps, compatible with the network operating system and cabling.
- Redundancy:
- PSU and Fans
- Ports:
- 1 serial, minimum 2 USB
- Operating System:
-
- ARIA:(8.0, 8.1, 8.5)
- Windows® 2000 Server Standard, Service Pack 4 (Server 25 client access license or sufficient seat licenses), or
Microsoft® Windows® Server 2003 R2 (Standard or Enterprise) with Service Pack 2 (25 client access license or sufficient seat licenses).
- ARIA (8.6):
- Microsoft® Windows® Server 2003 R2 (Standard or Enterprise) with Service Pack 2 (25 client access license or sufficient seat licenses).
- File System:
- NTFS
- Microsoft® OS Architecture
- 32-bit (not 64-bit)
- Microsoft® .NET Framework
- ARIA (8.0, 8.1, 8.5): 1.1 and 2.0 (not 3.0)
- ARIA (8.6): 1.1, 2.0 and 3.0
42U Half Height Rack systems come with the following components (see notes below):
- Cables for Keyboard and Video
- NEMA standard power strip
- 1U 8-port keyboard/monitor KVM switch box
- 1U keyboard/trackball and monitor console
- 2U 3000VA Uninterruptible Power Supply (UPS)
- 24-port patch panel (CAT5E)
Notes:
- Hardware used should be approved based on the current Microsoft® Windows® Catalog Listing.
- In addition to this Database Server, the following Image Fileserver is required for use with all image-based products and would be installed in the same rack.
- 1 Gbps network recommended for maximum speed and performance.
- The Operating System (build and version) on the Database Server shall match the Operating System (build and version) on the HARRP server.
- Specifications subject to change without prior notification.