Replacement X-ray Tubes by Manufacturer

 


Radiographic Rad/Fluoro Tubes
Tube Type Insert Type Focal Spot KW Rating Heat Units Target Angle KVP Range Data Sheet
DX71H/HS RAD-13 1.0-2.0 39/81 300 kHU 16° 150 kV RAD-13
DX81H/HS RAD-14 0.6-1.2 32/77 300 kHU 12° 150 kV RAD-14
DX91H/HS RAD-13 1.0-2.0 39/81 300 kHU 16° 150 kV RAD-13
DX93H/HS RAD-14 0.6-1.5 32/95 300 kHU 12° 150 kV RAD-14
DX96H/HS RAD-14 0.6-1.2 32/77 300 kHU 12° 150 kV RAD-14
RAD-21 0.6-1.2 36/100 300 kHU 12° 150 kV RAD-21
DX97H/HS RAD-14 0.6-1.2 32/77 300 kHU 12° 150 kV RAD-14
RAD-21 0.6-1.2 36/100 300 kHU 12° 150 kV RAD-21
DX10H/HS RAD-44 1.0-2.0 55/115 400 kHU 16° 150 kV RAD-44
DX101H/HS RAD-21 0.6-1.2 36/100 300 kHU 12° 150 kV RAD-21
A-196 0.6-1.0 32/72 350 kHU 12° 150 kV A-196
DX104H/HS A-196 0.6-1.0 32/72 350 kHU 12 150 kV A-196
RAD-60 0.6-1.2 40/100 400 kHU 12 150 kV RAD-60
DX106H/HS RAD-92 0.6-1.2 40/100 600 hKU 12° 150 kV RAD-92
DX304H/HS A-292 0.6-1.2 40/100 400 kHU 12° 150 kV A-292

Footnotes:

Note: Varian Sapphire housings mount directly into mounting clamp for Comet D07-10 housing.

Note: Please contact Varian Medical Systems if you require a replacement tube not identified above.

“All Trademarked terms are property of the respective manufacturer.”

Contact Us


 
Radiographic Rad/Fluoro
Tube Type Insert Type Focal Spot KW Rating Heat Units Target Angle KVP Range Data Sheet
S240 (MSN740) RAD-13 1.0-2.0 38/77 300 kHU 16° 150 KVP RAD-13
S240 (RSN742) CG-292 0.6-1.2 36/85 500 kHU 12° 150 KVP CG-292
S260 (RSN742) CG-292 0.6-1.2 36/85 500 kHU 12° 150 KVP CG-292
S550 (RSN722) G-292 0.6-1.2 40/100 600 kHU 12° 150 KVP G-292
S550 (RSN722) G-1092 0.6-1.2 40/100 1.0 MHU 12° 150 KVP G-1092
MX120 (RSN722) G-1092 0.6-1.2 40/100 1.0 MHU 12° 150 KVP G-1092

Mammography
System Type Insert Type Focal Spot KW Rating Heat Units Target Angle KVP Range Data Sheet
Senograph 500T/600T M-151 0.1-0.3 1.0/4.0 90 kHU 7°/12° 49 KVP M-151
Senograph 700T/800T M-153 0.1-0.3 1.0/4.0 90 kHU 7°/12° 49 KVP M-153
DMR M-152 0.1-0.3 2.5/4.0 90 kHU 49 KVP M-152

Footnotes: “All Trademarked terms are property of the respective manufacturer.”

Contact Us


Radiographic Rad/Fluoro Tubes
Tube Type Insert Type Focal Spot KW Rating Heat Units Target Angle KVP Range Data Sheet
PX1302 A-102 1.0-2.0 40/80 300 kHU 16° 150 kV A-102
PX1312 A-132 0.6-1.2 32/76 300 kHU 12° 150 kV A-132
PX1351 RAD-8 1.0-2.0 25/47 150 kHU 16° 125 kV RAD-8
PX1402 RAD-44 1.0-2.0 55/115 400 kHU 16° 150 kV RAD-44
PX1429 A-192 0.6-1.2 40/100 300 kHU 12° 150 kV A-192
PX1436 A-292 0.6-1.2 40/100 400 kHU 12° 150 kV A-292
PX1482 A-256 0.6-1.0 28/54 400 kHU 16° 150 kV A-256
Specify "S" or "Q" Type Stator

Footnotes: “All Trademarked terms are property of the respective manufacturer.”

Contact Us


Computerized Tomography Tubes
Computerized Tomography CT Tubes Insert Housing Type Heat Units Warranty Product Data Sheet
1800/2000 Sprint GS-1089 B160H 1.0 MHU 50,000 GS-1089
2400/2400 ELITE/2400 ELECT GS-1579 B180H 1.5 MHU 50,000 GS-1579
SeleCT GS-1584* B230H 1.5 MHU 50,000 GS-1584
1800/2000 Sprint GS-1587 B180H 2.0 MHU 50,000 GS-1587
HELICAT II GS-2077 B220H 2.0 MHU 100 kSec GS-2077
2400/2400 ELITE/2400 ELECT GS-2079 B210H 2.0 MHU 50,000 GS-2079
SeleCT GS-3074* B245H 3.5 MHU 100,000 GS-3074
CT-TWIN/HELICAT GS-3077 B240H 3.5 MHU 300 kSec GS-3077
CT-TWIN/HELICAT/FLASH/RTF GS-5079 B502H 5.0 MHU 300 kSec GS-5079
CT-TWIN/HELICAT/RTF GS-6079 B502H 7.0 MHU 100 kSec GS-6079
SeleCT (HE350)

Footnotes:

*Note: Tubes are supplied without Heat Exchanger. Heat Exchanger (HE350) to be ordered separately.

Pricing includes housing value. Credit will be issued upon return of housing.

“All Trademarked terms are property of the respective manufacturer.”

Contact Us


Radiographic Rad/Fluoro Tubes
Tube Type Insert Type Focal Spot KW Rating Heat Units Target Angle KVP Range Data Sheet
RAD-8 Emerald 1.0-2.0 25/47* 150 kHU 16° 125 KVP RAD-8
RAD-12 Diamond 0.6-1.2 22/50 150 kHU 12.5° 150 KVP RAD-12
RAD-74 Emerald 0.6-1.5 19.8/52 200 kHU 14° 125 KVP RAD-74
RAD-68 Diamond 1.0-2.0 54/96 300 kHU 14° 150 KVP RAD-68
RAD-68 Diamond 0.6-1.2 29/64 300 kHU 14° 150 KVP RAD-68
RAD-10 Diamond 0.75-1.25 19.8/41.2 300 kHU 16° 150 KVP RAD-10
RAD-13 Diamond 1.0-2.0 39/81 300 kHU 16° 150 KVP RAD-13
RAD-14 Diamond 0.6-1.2 32/77 300 kHU 12° 150 KVP RAD-14
RAD-14 Diamond 0.3-1.2 7.5/77 300 kHU 12° 150 KVP RAD-14
RAD-14 Diamond 0.6-1.5 32/95 300 kHU 12° 150 KVP RAD-14

Footnotes: “All Trademarked terms are property of the respective manufacturer.”

Contact Us


 
CT Tubes
Scanner Type Insert Housing Type Heat Units Warranty Product Data Sheet
CT-MAX S-270 B150H 400 hKU 40,000 S-270
CT-MAX GS-270 B150H 600 kHU 40,000 GS-270
Sytec 1600/1800 GS-270 B150H 600 kHU 40,000 GS-270
CT 8800/9000 GS-1079 B190 1.0 MHU 40,000 GS-1079
CT8800 FS/CT9000 (Dual Heat Exchanger GS-1575 B192 1.5 MHU 50,000 GS-1575
CT9800 HILIGHT GS-2076K B205 2.0 MHU 50,000 GS-2076K
CT 9800 Q GS-2076 B205 2.0 MHU 50,000 GS-2076
Sytec 2000/3000/4000/i* GS-1562 MX115/B175H 1.5 MHU 80,000 GS-1562
HILIGHT ADVANTAGE GS-2176 Jupitor 2.0 MHU 80,000 GS-2176
Sytec SRI GS-2176 Mini Venus 2.0 MHU 80,000 GS-2176
Pro Speed A/I,CT/e GS-2276 MX135CT-H1 2.0 MHU 80,000 GS-2276
HiSpeed Advantage GS-3576HS Zeus 3.5 MHU 120,000 GS-3576HS
ProSpeed GS-3576PS ProSpeed 3.5 MHU 90,000 GS-3576PS
Solarix Dxi, Fxi, LXi GS-3576S Solarix 3.5 MHU 120,000 GS-3576S

Portables
System Type Insert Type Focal Spot KW Rating Heat Units Target Angle KVP Range Data Sheet
AMX 4 RAD-10 0.75 19.8 300 kHU 16° 150 KVP RAD-10
AMX 3 RAD-10 0.75 19.8 300 kHU 16° 150 KVP RAD-10
AMX 2 A-102 1.0-2.0 40/80 300 kHU 16° 150 KVP A-102
AMX 110 A-102 1.0-2.0 40/80 300 kHU 16° 150 KVP A-102
AMX4+ RAD-11 0.8 22 300 kHU 14° 125 KVP RAD-11

Mammography
System Type Insert Type Focal Spot KW Rating Heat Units Target Angle KVP Range Data Sheet
Senograph 500T/600T M-151 0.1-0.3 1.0/4.0 90 kHU 7°/12° 49 KVP M-151
Senograph 700T/800T M-153 0.1-0.3 1.0/4.0 90 kHU 7°/12° 49 KVP M-153
DMR M-152 0.1-0.3 2.5/4.0 90 kHU 49 KVP M-152

Radiographic Rad/Fluoro
Tube Type Insert Type Focal Spot KW Rating Heat Units Target Angle KVP Range Data Sheet
MX75/HRT A-102 1.0-2.0 40/80 300 kHU 16° 150 KVP A-102
A-132 0.6-1.2 32/76 300 kHU 12° 150 KVP A-132
MX100 A-195 0.6-1.2 40/100 350 hKU 12° 150 KVP A-195
A-196 0.6-1.0 32/72 350 hKU 12° 150 KVP A-196
G-292 0.6-1.2 40/100 600 hKU 12° 150 KVP G-292
MX100FLXR A-195 0.6-1.2 40/100 350 kHU 12° 150 KVP A-195
A-196 0.6-1.0 32/72 350 kHU 12° 150 KVP A-196

Special Procedures
OEM Tube Insert Housing Focal Spot KW Rating Heat Units Target Angle Data Sheet
MX100HTC G-1078 Grid MX100 HTC II 0.6-1.0 48/90 1.0 kHU G-1078 Grid
MX100HTG G-1078 Grid MX100HTG 0.6-1.0 48/90 1.0 kHU G-1078 Grid

Footnotes: Pricing includes housing value. Credit will be issued upon return of housing. “All Trademarked terms are property of the respective manufacturer.”

Contact Us


 
CT Tubes
Scanner Type Insert Housing Type Heat Units Warranty Product Data Sheet
Tomoscan T-60 S-780 B160H 750 kHU 50,000 S-780
Tomoscan TX, CX GS-1580 B180H 1.5 MHU 60,000 GS-1580
Tomoscan LX, LXC GS-2070 B200H 2.0 MHU 60,000 GS-2070
Tomoscan AV-Pf, Tomoscan SR4000 GS-2072 B200H 2.0 MHU 60,000 GS-2072
Tomoscan SR5000, Tomoscan SR6000 GS-3070 B240H 3.5 MHU 60,000 GS-3070
Tomoscan GS-3072 B240H 3.5 MHU 60,000 GS-3072

Radiographic Rad/Fluoro
Tube Type Insert Type Focal Spot KW Rating Heat Units Target Angle KVP Range Data Sheet
SRO 25/50 PG-256 0.6-1.0 35/50 500 kHU 16° 150 KVP PG-256
RAD-50 0.6-1.0 31.5/52.5 325 kHU 15° 150 KVP RAD-50
SRO 33/100 PG-292 0.6-1.2 36/85 500 kHU 12° 150 KVP PG-292
RAD-34 0.6-1.2 36/85 325 kHU 12.5° 150 KVP RAD-34

Special Procedures
OEM Tube Insert Housing Focal Spot KW Rating Heat Units Target Angle Data Sheet
SRM 03/10 P-483 ROT 500/ROT 501 0.3-1.0 10/80 800 kHU 10° P-483
SRM 35/100 P-493 ROT 500/ROT 501 0.6-1.2 35/100 800 kHU 12° P-493
SRM 22/50 P-456 ROT 500/ROT 501 0.5-1.0 22/50 400 kHU 15° P-456

Footnotes: “All Trademarked terms are property of the respective manufacturer.”

Contact Us


Computerized Tomography Tubes
Computerized Tomography CT Tubes Insert Housing Type Heat Units Warranty Product Data Sheet
Picker SX MEGA GS-1096 B160 1.0 MHU 30,000 GS-1096
1200SX MEGA HDT GS-2096 B225 2.0 MHU 50,000 GS-2096
IQ PREMIER GS-2086IQ B242 2.0 MHU 50,000 GS-2086IQ
PQ2000 GS-2086PQ B242 2.0 MHU 60,000 GS-2086PQ
Picker 5.0 PQ Series GS-5076 B590H 5.0 MHU 100,000 GS-5076
Picker 6.5 PQ Series GS-6076 B590H 6.5 MHU 120,000 GS-6076

Footnotes:

Note: CN164 – PICKER Synerview (GS1096) Trunnion Rings for B160 Housing.

CN184 – PICKER Synerview (GS2096) Trunnion Rings for B180 and B225 Housings.

 

Pricing includes housing value. Credit will be issued upon return of housing.

“All Trademarked terms are property of the respective manufacturer.”

Contact Us


Radiographic Rad/Fluoro Tubes
Tube Type Insert Type Focal Spot KW Rating Heat Units Target Angle KVP Range Data Sheet
O.6/1.2P18C - RX80 RAD-21 0.6-1.2 36/100 300 kHU 12° 150 KVP RAD-21
0.6/1.2P38C-RX80 RAD-21 0.6-1.2 36/100 300 kHU 12° 150 KVP RAD-21
0.6/1.2P38DE-RX80 RAD-21 0.6-1.2 36/100 300 kHU 12° 150 KVP RAD-21
1/2P13C-RX80 RAD-44 1.0-2.0 55/120 400 kHU 16° 150 KVP RAD-44
1/2P33D-RX80 RAD-44 1.0-2.0 55/120 400 kHU 16° 150 KVP RAD-44

Footnotes:

Note: 1) RX100 Housings can be reloaded.

2) Please contact Varian Medical Systems if you require a replacement tube not identified above.

“All Trademarked terms are property of the respective manufacturer.”

Contact Us


 
CT Tubes
Scanner Type Insert Housing Type Heat Units Warranty Product Data Sheet
Somatom CR/DR GS-2030 B300 2.0 MHU 50,000 GS-2030
Somatom DRG/DRH GS-2030 B300 2.0 MHU 50,000 GS-2030
Somatom HI-Q GS-2030 B300 2.0 MHU 50,000 GS-2030

Radiographic Rad/Fluoro
Tube Type Insert Type Focal Spot KW Rating Heat Units Target Angle KVP Range Data Sheet
OPTI/SV 150/30/50C SG-256B 0.6-1.0 32/60 600 kHU 16° 150 KVP SG-256B
OPTI/SV 150/40/82C SG-292B 0.6-1.2 40/100 600 kHU 12° 150 KVP SG-292B
OPTI/SV 150/40/73C SG-296B 0.6-1.0 40/70 600 kHU 12° 150 KVP SG-296B
OPTI/SV 150/40/80C SG-796B 0.6-1.0 40/80 600 kHU 12° 150 KVP SG-796B
OPTITOP 150/40/80 SG-1096 0.6-1.0 40/80 840 kHU 12° 150 KVP SG-1096
Note: Specify 2 phase or 3 phase stator

Special Procedures
OEM Tube Insert Housing Focal Spot KW Rating Heat Units Target Angle Data Sheet
Megalix 125/40/82C SG-1392 Opti150 0.6-1.0 40/82 1.3 MHU 12° SG-1392
Megalix 125/30/82C(G)M* SG-1560 Megalix / Megalix W 0.4-0.8 30/82 1.35 MHU SG-1560
Megalix 125/40/82CM SG-1590BI Megalix / Megalix W 0.6-1.0 40/82 1.3 MHU 12° SG-1590BI
Megalix 125/15/40/82 CGM SG-1590TRI Megalix / Megalix W 0.3-0.6-1.0 15/40/82 1.35 MHU 12° SG-1590TRI

Footnotes:

Pricing includes housing value. Credit will be issued upon return of housing.

* Specify Grid

Note: Specify 2 phase or 3 phase stator

“All Trademarked terms are property of the respective manufacturer.”

Contact Us


 
Radiographic Rad/Fluoro
Tube Type Insert Type Focal Spot KW Rating Heat Units Target Angle KVP Range Data Sheet
E7239X RAD-8 1.0-2.0 25/47 150 kHU 16° 125 KVP RAD-8
E7242X RAD-74 0.6-1.5 19.8/52 200 kHU 14° 125 KVP RAD-74
E7834X RAD-12 0.6-1.2 22/50 150 kHU 12.5° 150 KVP RAD-12
E7813X RAD-13 1.0-2.0 55/110 300 kHU 16° 150 KVP RAD-13
E7252X RAD-14 0.6-1.2 27/75 300 kHU 12° 150 KVP RAD-14
E7251X RAD-21 0.6-1.2 36/100 300 kHU 12° 150 KVP RAD-21
DRX-3635 A-197 0.3-0.8 11/49 300 kHU 12° 150 KVP A-197
DRX-3724 A-192 0.6-1.2 40/100 300 kHU 12° 150 KVP A-192
DRX-3725 A-286 0.3-1.2 8.5/100 400 kHU 12° 150 KVP A-286
DRX-3603 RAD-44 1.0-2.0 55/115 400 kHU 16° 150 KVP RAD-44

Special Procedures
OEM Tube Insert Housing Focal Spot KW Rating Heat Units Target Angle Data Sheet
DRX-6334 G-1582B B180H 0.6-1.0 55/112 1.5 MHU 10° G-1582B
DRX-6434 G-1582BI B180H 0.6-1.0 55/112 1.5 MHU 10° G-1582BI
DRX-G15345 G-1582TRI B180H 0.6-0.6-1.0 18/60/42 1.5 MHU 10° G-1582TRI

Footnotes: “All Trademarked terms are property of the respective manufacturer.”

Contact Us

 

 

Contact Immediate Delivery XRP

X-Ray Products - Interay
Headquarters

Tel: 843.767.3005
Fax: 843.760.0079
E-Mail: interay.sales@varian.com

© 1999-2008 Varian Medical Systems, Inc. All rights reserved.
Production of any of the material contained herein in any format or media without the express written permission of Varian Medical Systems is prohibited.

North America EMEA - Europe, Middle East, India & Africa